How to use search function?

Use our advanced search function and find what you are looking for as quick as a flash.

Endovascular

Peripheral angioplasty catheter LOVIX OTW/RX

Medical use
Peripheral angioplasty
Basic UDI-DI
5901297PBCF6

Peripheral angioplasty catheter, OTW, Lovix, is intended for dilating of de novo or restenotic atherosclerotic lesions in patients with symptomatic peripheral artery disease as well as for the post-delivery expansion of a peripheral stent (postdilatation).

Lovix peripheral angioplasty catheter, OTW, consists of:

  • Y- hub;
  • dual lumen polyamide tube (first lumen for guidewire, second for filling balloon);
  • polyamide balloon.

It has two radiopaque markers to identify cylindrical portion of the balloon, that enables the stent positioning within the treated lesion.

Peripheral angioplasty catheter LOVIX RX consists of:

  • distal part - has a dual lumen. The outer lumen is used to inflate the balloon, and the inner lumen is used for moving the catheter over a guidewire. The distal section of the catheter has a hydrophilic coating. At the end of the catheter there is a semi-compliant balloon with two radiopaque markers allowing placing of the balloon in relation to treated lesion. The balloon is designed to inflate to a defined diameter at recommended pressure.
  • proximal part - consists of a stainless steel hypotube covered with fluoropolymer and a hub with a single female luer-lock connector for inflation and deflation of the balloon.

The balloon is delivered to the intended lesion site and inflated, restoring patency of the vessel.

Intended purpose:

Peripheral Angioplasty Catheter Lovix is intended for dilating of de novo or restenotic atherosclerotic lesions in patients with symptomatic peripheral artery disease, as well as for the post-delivery expansion of a peripheral stent (postdilatation).

    Technical data overview

    WITH DELIVERY SYSTEM OVER THE WIRE (OTW)

    Balloon material  nylon
    Balloon diameter 1.50-16.00 mm
    Balloon length 20-250 mm
    Nominal pressure (for balloon diameters 5.00-7.00  mm) 8 atm
    Nominal pressure (for balloon diameters 8.00-16.00 mm)  6 atm
    Deflated time short
    Pushability and trackability excellent
    Delivery system  Over The Wire (OTW)
    Delivery system lengths 80 cm, 100 cm, 120 cm, 135 cm, 170 cm
       

     

    WITH DELIVERY SYSTEM RAPID EXCHANGE (RX)

    Balloon material  nylon 
    Balloon diameters  1.25-7.00 mm
    Balloon lengths  10-250 mm
    Nominal pressure (for balloon diameters 1.25-4.50 mm) 10 atm
    Nominal pressure (for balloon diameters 5.00-7.00 mm) 8 atm
    Deflated time  short 
    Pushability and trackability  excellent 
    Compatible guidewire   max 0.014”
    Delivery system  Rapid Exchange (RX)
    Delivery system lengths 140 cm
       

    Available versions

    WITH DELIVERY SYSTEM OVER THE WIRE (OTW)

    Reference: Nominal balloon
    diameter [mm]
    Nominal balloon
    length [mm]
    Use with guidewire Use with
    introducer [F]
    Catheter length
    [cm]
    Nominal pressure
    [atm]
    B C E
    PBABxCE110 1.5 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100  0.018
    0.025
    4 110 10
    PBABxCE110 1.5 120, 150, 200, 250 0.025 4 110 10
    PBABxCE110 2 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018
    0.025
    4 110 10
    PBABxCE110 2 120,150, 200, 250 0.025 4 110 10
    PBABxCE110 2.5 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018
    0.025
    4 110 10
    PBABxCE110 2.5 120, 150, 200, 250 0.025 4 110 10
    PBABxCE110 3 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018
    0.025
    4 110 10
    PBABxCE110 3 120, 150, 200, 250 0.025 4 110 10
    PBABxCE110 4 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.018
    0.025
    0.035
    5 110 10
    PBABxCE110 4 120, 150, 200, 250 0.035 5 110 10
    PBABxCE110 5 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 120 0.025
    0.035
    5 110 8
    PBABxCE110 5 150, 200, 250 0.035 6 110 8
    PBABxCE110 6 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 120 0.025 5 110 8
    PBABxCE110 6 150, 200, 250 0.035 6 110 8
    PBABxCE110 7 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95,100, 0.035 5 110 8
    PBABxCE110 7 120, 150,200, 250 0.035 6 110 8
    PBABxCE110 8 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 5 110 6
    PBABxCE110 9 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 6 110 6
    PBABxCE110 10 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 6 110 6
    PBABxCE110 12 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 7 110 6
    PBABxCE110 14 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 8 110 6
    PBABxCE110 16 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.035 8 110 6

     

    WITH DELIVERY SYSTEM RAPID EXCHANGE (RX)

    Reference: Nominal
    balloon diameter
    [mm]
    Minimum Guiding
    Catheter I.D.
    [inch]
    Nominal
    pressure
    [atm]
    Nominal
    balloon length
    [mm]
    B C
    PBARXBxC140 1.25 0.056 10 10, 15, 20, 25, 30, 35, 40
    PBARXBxC140 1.5 0.056 10 10, 15, 20, 25, 30, 35, 40
    PBARXBxC140 1.75 0.056 10 10, 15, 20, 25, 30, 35, 40
    PBARXBxC140 2 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 2.25 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 2,5 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 2.75 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 3 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 3.25 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 3.5 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 3.75 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 4 0.056 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 4.5 0.064 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 5 0.067 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 5.5 0.067 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 6 0.067 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 6.5 0.067 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250 
    PBARXBxC140 7 0.071 8 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 150, 180, 200, 250